Before installing the floor drain, the floor drain core must be removed, so as to prevent debris from falling into the floor drain core and causing damage.

How to install the floor drain? Installation Precautions?

For common situations, the precautions for floor drain installation are as follows:

1. Before installing the floor drain, the floor drain core must be removed, so as to prevent debris from falling into the floor drain core and causing damage.

2. The purpose of installing the floor drain is for drainage, so the installation position of the floor drain should be slightly lower than the ground to facilitate drainage. Before the floor drain is installed, if the drain pipe is too close to the ground, the drain pipe should be cut appropriately to ensure that the panel of the installed floor drain is slightly lower than the ground.

3. In order to ensure that the overall decoration effect is not damaged, the installation position of the floor drain should not be too much lower than the ground. Therefore, if the drainage pipe is too far from the ground, it should be filled with cement mortar, so that the purpose of raising the drainage pipe can be achieved. Only after installation can the Z perfect decorative effect be guaranteed.

4. When installing the floor drain, in order to prevent tools and other items from falling into the drain pipe and causing blockage, block the drain pipe with cloth or other soft items in advance, and take it out when the floor drain core is installed.

5. The installation of the floor drain should take into account the convenience of future maintenance. Therefore, when filling the cement mortar, the floor drain should not be used directly. Instead, use kraft paper or other strong materials to roll into a cylinder that matches the sewer pipe, and connect with the sewer pipe. Raised above the ground and then filled with cement mortar.

6. The floor drain is docked with the sewer pipe and is higher than the ground. Fill the mixed cement mortar (1:1) into the surrounding space, adjust the height of the floor drain panel to a suitable position, and after the cement mortar solidifies, put the floor drain into the It is formed into a pipeline, so that it closely fits with the pipe wall.

7. If the floor drain used by the washing machine, you can purchase a special washing machine floor drain or connector. Of course, you can also use the ordinary floor drain directly. You only need to insert the drain pipe sleeve on the fixing pin on the upper part of the floor drain. It is just practical. And convenience is not as good as the former two.