Improve the floor height of the living room to eliminate the sense of depression
Release time:
2026-05-15
The floor height of the home directly affects whether there is a sense of depression in living, so many people like to make a fuss on the ground during the decoration process, but did you know that the ground height of the entrance door
The floor height of the home directly affects whether there is a sense of depression in living, so many people like to make a fuss on the ground during the decoration process, but did you know that the ground height of the entrance door, bathroom and bedroom is very particular, and even paving bricks or paving Wood floors will affect the height of the ground. So, what should we pay attention to when the storey height is extended?
The floor drain is placed on one side of the floor tile
The floor height of the rough house may not be the floor height when you move in in the future, so what determines the indoor floor height? You may not believe that the bathroom floor drain will be an important factor. Under normal circumstances, the indoor floor height will have two natural heights. The floor of the bathroom and kitchen is basically the same height, and the floor of the rest of the living room, dining room, bedroom and other spaces is the same height. Among these two heights, the floor height of the bathroom and kitchen will be about 3 cm lower than the height of the living room and other floors. This is because the floor of the kitchen and bathroom has floor drains, and there may be a small area of short-term water accumulation on the ground, which is reasonable. The drop will not allow the water to overflow elsewhere.
In the same way, in order to make the water on the floor of the kitchen and bathroom flow to the floor drain quickly, the floor must have a reasonable slope. According to the requirements of the indoor construction process, the inclination of the bathroom floor must reach 2%, that is to say, the height of the floor drain will be the low point of the slope, and the ground of the bathroom will be taken as the low point and raised upward, and the height of the room will also be affected. Therefore, if you change the water or the treatment pipeline, the height of the floor drain is better to be lower than higher. The location of the floor drain is placed on one side of the floor tile, because if it is in the middle of the tile, it is difficult to reach the low point of the floor drain no matter how the tile is inclined.
The ground of the rough house should be leveled and then paved with bricks
In order to save trouble, some owners ask bricklayers to lay bricks after entering the site, which is extremely inadvisable, because the ground of the rough house may not be leveled. Under normal circumstances, when laying tiles, the thickness of the cement mortar should be about 3 cm, but if it is simply done at this height, the ground is likely to be uneven; but some owners will say, this is very simple, if the ground If there is a high point, it is just covered with cement mortar, and the ground will be level. But this is not the case. If the thickness of the cement mortar is less than 3 cm, the adhesion between the tiles and the ground cannot be guaranteed. In other words, there is a great danger of hollowing, so it is very important to level the rough ground before laying tiles.